Reference infrastructure. Professional RTK devices.
HUGEROCKRTKGO
◎ English
English简体中文
Request a quote ↗
GB30 / LOCAL BASE + NTRIP CASTER

RTK base station.
NTRIP Caster. One GB30.

Build your own GNSS reference service with GB30: an integrated local base station and NTRIP Caster on a low-power ARM platform. Connect professional RTK handhelds, field tablets, rovers and industry terminals.

Complete kit · Quotation on request · GB30 main unit: 1.5W typical / 2W full load

GB30 complete reference kit with main unit, external GNSS antenna, stand and coaxial cable
↗
ONE COMPACT PLATFORMBase + Caster
◎
NETWORK TUNNELNo public IP required
Main unit · GNSS antenna · stand · antenna cable
Base + CasterOne integrated GB30 platform
1.5WTypical power / 2W at full load
256 + 8Default client terminals + uplink stations
4,000Up to 4,000 simultaneous clients in direct NTRIP mode
THE REFERENCE-TO-FIELD SYSTEM

Small footprint.
Connected possibilities.

Follow the correction data, from a fixed reference point to professional RTK equipment.

GB30 indoor reference installation with outdoor antenna and connected coaxial cable
01 / ESTABLISH THE REFERENCEOne complete kitMain unit · external GNSS antenna · mounting stand · coaxial cable
01 / ESTABLISH THE REFERENCE

A fixed point.
A dependable starting point.

GB30 indoor reference installation with outdoor antenna and connected coaxial cable

Place the GNSS antenna at a stable outdoor reference location. Keep the GB30 main unit protected indoors, with DC power and the antenna cable connected to its SMA input. USB-C is for debugging only.

One complete kitMain unit · external GNSS antenna · mounting stand · coaxial cable
Review the installation ↗
02 / CONNECT THE NETWORK

One compact platform.
Base and Caster, together.

GB30 reference platform

In Local Base Station mode, GB30 serves its own reference source and up to eight independent uplink sources. Choose direct NTRIP or a compatible network tunnel for your deployment.

1.5W typicalGB30 main unit · 2W at full load · external equipment excluded
Explore the Base + Caster ↗
03 / PUT CORRECTIONS TO WORK

From your reference.
To the work that matters.

G71M rugged RTK tablet in a professional field application, illustration

Connect professional RTK handhelds, rugged tablets, mobile rovers, machine terminals and other compatible industry equipment. Select the reference mountpoint suited to each work area.

Reference to fieldSurveying · agriculture · construction · vehicle integration
Find your application ↗

Network diagram and application scenes are illustrative. Reference sources remain independent; coverage and positioning performance depend on the installation and operating conditions.

FIXED REFERENCE INSTALLATION

Indoor GB30.
Outdoor antenna.

A fixed reference point begins with the right installation.

  1. Fix the antenna.

    Mount the GNSS antenna outdoors at a stable reference location with a clear view of the sky.

  2. Connect the DC and SMA.

    Connect the DC supply to the round power input and the antenna coax to the gold SMA input. Leave USB-C disconnected during normal operation; it is for debugging only.

  3. Configure and verify.

    Connect to an available network, choose the operating role, then check source and client status.

Illustrated fixed installation: outdoor GNSS antenna, coaxial cable and indoor GB30 with SMA connection
Fixed outdoor antenna · protected indoor GB30
GB30 local base interface showing GNSS, network, NTRIP and system status

Monitor GNSS, network and correction-service status from the built-in display.

VISIBLE OPERATION

Know what your
reference service is doing.

Review the running state from the built-in display.

GNSS

Reference position, satellite signals and receiver status.

Network

Connectivity, signal strength and service reachability.

NTRIP

Client connections and correction data activity.

System

Memory and processor activity.

TWO CONNECTION PATHS

Connect the way
your site needs.

Direct NTRIP and network tunnelling support different network environments.

DIRECT NTRIP

A reachable reference service.

Connect compatible industrial RTK devices through a direct NTRIP connection.

  • Up to 4,000 simultaneously online clients.
  • Default configuration: 256 client terminals.
  • Requires a reachable NTRIP service, such as a suitable local network or public IP setup.
NETWORK TUNNEL

Less network configuration.

Connect through a tunnel where a dedicated public network setup is unavailable.

  • No public IP. No port forwarding. No dedicated line.
  • Internet access and a compatible tunnel client are required.
  • The 4,000-client direct NTRIP figure is not a tunnel capacity claim.
CITY REFERENCE NETWORKS

Nine reference points.
One GB30 hub.

Eight uplink GB30 stations provide independent reference sources to one GB30 in Local Base Station mode.

The central GB30 serves its own source, L00, and the eight uplink sources, U01–U08. Field terminals can access a nearby source for their work area.

Separate sources remain independent. Select the mountpoint suited to each work area; reference streams remain independent.

U01GB30 uplink source
U02GB30 uplink source
U03GB30 uplink source
U04GB30 uplink source
L00Local base + Caster
U05GB30 uplink source
U06GB30 uplink source
U07GB30 uplink source
U08GB30 uplink source

Illustrative 8 + 1 layout · approximately 10km between adjacent reference points. Actual service coverage depends on site conditions and positioning requirements.

THE FIELD DEVICE RANGE

The right RTK device.
Built for your work.

Rugged handhelds, field tablets and a dedicated vehicle terminal.

Explore & compare devices →
HUGEROCK / INDUSTRIAL MOBILE COMPUTING

Smarter Industry, Safer Work

About HUGEROCK ↗

HUGEROCK develops rugged handhelds, tablets and fixed terminals for industrial work, supported by industrial design, hardware, software and production capabilities.

RTKGO connects GB30 reference infrastructure with professional RTK field devices.

Discuss your RTK project →
01 / RUGGED DEVICES

Designed for industrial work.

Handhelds, tablets and fixed terminals for field and operational workflows.

02 / REFERENCE TO FIELD

A connected RTK workflow.

Reference services and professional RTK devices for your project.

Plan your reference-to-field workflow.

Choose the infrastructure, devices and connection path for your operation.

Configure an enquiry↗
APPLICATION & SELECTION

RTK correction infrastructure, from reference to field

HUGEROCK RTKGO brings fixed GNSS reference infrastructure and professional RTK devices into one deployment workflow. Start with a GB30 complete reference kit, then select field equipment and a correction-data connection for your application.

What is the difference between an RTK base station and an NTRIP Caster?

A GNSS reference base generates correction data from a fixed reference point. An NTRIP Caster distributes correction streams to compatible clients. In Local Base Station mode, GB30 performs both functions in the same device.

Which RTK equipment can connect to GB30?

Compatible RTK handhelds and tablets, rovers, agricultural and vehicle positioning terminals, and robotics positioning systems can receive corrections. Direct NTRIP requires a reachable service; network tunnels require internet access and compatible client software.

OFFICIAL BLOG / RTKGO INSIGHTS

From installation.
To informed decisions.

Explore the official blog →

Compare selected devices.